High power quality
The Galaxy 6000 range supplies clean stable power to sensitive loads to ensure.
Optimum operation.
Extended life.
On-line double conversion providing clean output waveform whether the mains is present or not.
Stable output voltage: load variations have minimal effect.
Output voltage total harmonic distortion (THDU) less than 3%.
Architectures for all requirements
Paralleling for Redundant or power uplift.
Paralleling of six modules with external static by-pass switch or up to 4 without static by-pass.
Redundant distribution with Upsilon STS.
Very high efficiency – minimised total cost of ownershipe
The efficiency of UPSs delivering several hundred kVA is critical.
The Galaxy 6000 range has variable frequency DSP PWM control to maximise efficiency.
Computer controlled battery management for assured backup time
24/7 non-stop operation with Digibat B1000 and Cellwatch battery management systems.
Communications
The Galaxy 6000 range can be connected to all type of networks
To communicate the UPS status.
To shut down the operating systems of the servers connected, automatically in a controlled manner.
To be supervised as part of a group of UPSs.
Extensive list of standard features
On-line double conversion architecture (EN50091 Voltage and Frequency Independent UPS) with built in static switch and manual by-pass or with system by-pass static switch.
Soft start, walk-in charger and inrush current limit for compatibility with generator sets.
Can start without mains (cold start).
Circuit breaker for deep discharge protection.
Modular paralleling (up to 6).
Paralleling up to 6 UPSs with centralised external static switch.
Sequential start-up for UPSs (in parallel configuration) to reduce impact on Genset.
True front access, can be installed against a wall.
Centralised static switch: 500 kVA to 4.8 MVA.
Emergency stop (EPO).
|
|
"Vision" option for easy and effective operation
High definition tactile colour display (32cm, 800x600 SVGA).
Animated mimic display.
Event log.
Metering.
Statistics.
Remote viewing using a Web browser.
Display on each module of a parallel configuration or on only one UPS to supervise all the modules.
All the options you need
Total Harmonic Management active harmonic filters and choice of passive harmonic filters.
12 Pulse rectifier.
External by-pass cubicle (1200 kVA).
"Vision" interface : large, color, tactile display.
Isolation transformers.
Remote LED indicator panel + Telemonitor.
Battery monitoring (monitoring each battery block).
Battery circuit breaker unit.
Synchronisation module.
Top cable entry.
Common normal and bypass AC inputs.
|